 Corcom Facility EMI Filters Product Guide CDSUX-C Series - Extended Range Buffer Networks
Catalog: 1654986 Issue Date: 11.2009
CDSUX-C Series
Features
* Sealed, constructed of 16 gauge cold rolled steel * All non-conductive surfaces protected with suitable painting or electroplating * Removable input cover for terminal access and field wiring connection * Threaded conduit fitting with flexible lead on the load side * Knockouts provided on the input side * Discharge bleeder resistor provided to reduce shock hazard * Surge protector provided upon request
6P16
Electrical Characteristics
Voltage Drop:
Less than 1% @ unity power factor
Overload:
140% of rated current for 15 minutes
Harmonic Distortion:
Less than 2% @ full rated current
Dielectric Withstanding Voltage:
Per MIL-PRF-15733 and UL1283
D.C. Insulation Resistance:
Per MIL-STD-202, Method 302
Terminal Strength:
Per MIL-STD-202, Method 211, Condition E
Temperature Rise:
Per MIL-PRF-15733 and UL1283
R.F. Radiation:
100 dB minimum shielding effectiveness
Insertion Loss:
100 dB from 14 kHz - 10 GHz per MIL-STD-220A, under load condition, using extended range buffer networks over the frequency range of 14 kHZ - 20 MHz
Applicable Publications:
MIL-PRF-15733 -- Filters, radio interference MIL-STD-202 -- Test methods for Components
How to Order:
CDSUX 2 030 A6 - C - S
Surge Arrestors (optional) Conduit Fitting (supplied) Voltage/Frequency
A6 - 120/208V, 60Hz B6 - 277/480V, 60Hz A4 - 120/208V, 400Hz
1
MIL-STD-220A -- Test method of Insertion Loss
MIL-STD-285 -- Test method for Shielding Effectiveness NFPA 70-1987 -- National Electric Code 486A - 1983 -- Wire Connectors and Lug UL1283 -- Underwriter Laboratories
Current Rating 2 # of Filters Series
Examples: CDSUX2030A6-C-S, CDSUX1010B6-C
Note 1: Surge Arrestor for A6/A4* Models: V251BA60 Surge Arrestor for B6 Models: V481BA60 Current configuration listed as 3 digits with leading zeros
Note 2:
60 Hz Models Only
16
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
USA Cust. Svc.: Corcom Prods:
1-800-468-2023 1-847-680-7400
www.tycoelectronics.com www.corcom.com
Corcom Facility EMI Filters Product Guide CDSUX-C Series - Extended Range Buffer Networks
A F
Catalog: 1654986 Issue Date: 11.2009
(continued)
Label
Label
B
E
Label
Knockouts for 0.75 (19.05) & 1.0 (25.4) Conduit 3 Places
D 1/2 D
2
Corcom Facility EMI Filters -- Stand-Alone Filters
C
2.0 50.8
14.0 1.0 355.6 25.4
Ground Stud & Lug
1.0 (25.4) NPT Supplied with RF Gasket, Flange Nut and Insulating Bushing
Insulated wire Type THHN
CDSUX 1010**-C 2010**-C 1030**-C 2030**-C 1060**-C 1100**-C 1150**-C 1225**-C
Current (Amps) 10 2 x 10 30 2 x 30 60 100 150 225
Dimensions A .063 [1.6] B 21.0 533.4 21.0 533.4 26.0 660.4 26.0 660.4 32.0 812.8 34.0 863.6 41.0 1041.4 41.0 1041.4
.063 [1.6] C .063 [1.6]
4.0 101.6 8.0 203.2 6.0 152.4 12.0 304.8 8.0 203.2 8.0 203.2 10.0 254.0 10.0 254.0
5.0 127.0 5.0 127.0 6.0 152.4 6.0 152.4 6.0 152.4 6.0 152.4 6.0 152.4 6.0 152.4
D 5.0 127.0 5.0 127.0 5.0 127.0 5.0 127.0 6.0 152.4 8.0 203.2 9.0 228.6 9.0 228.6
E 3.0 76.2 5.5 139.7 4.0 101.6 9.0 228.6 5.5 139.7 5.5 139.7 9.0 228.6 9.0 228.6
F .31 x .50 7.87 x 12.7 .43 x .75 10.9 x 19.1 .31 x .50 7.87 x 12.7 .43 x .75 10.9 x 19.1 .43 x .75 10.9 x 19.1 .43 X .75 10.9 x 19.1 .43 X .75 10.9 x 19.1 .43 X .75 10.9 x 19.1
Wire Gauge (AWG/mm2) 10 5.26 10 5.26 6 13.20 6 13.20 6 13.20 2 33.6 0 53.5 250 MCM 126.0
Approx. Weight (Pounds/KG) 15 6.80 30 13.6 30 13.6 60 27.2 60 27.2 70 31.8 90 40.8 120 54.4
*400Hz filters available upon request. Will require external power factor correction coil. Please contact Tyco Electronics Application Engineering 847-573-6517.
Max. Operating Voltage A6: 120/208V, 60 Hz B6: 277/480V, 60 Hz A4*: 120/208V, 400 Hz
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
USA Cust. Svc.: Corcom Prods:
1-800-468-2023 1-847-680-7400
17
www.tycoelectronics.com www.corcom.com


▲Up To Search▲   

 
Price & Availability of CDSUX1030A4-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X